热门搜索: 在线监测硫酸浓度设备 MPR E-Scan 安装便捷 MPR E-Scan 硫酸浓度分析仪 化工行业优选 浓硫酸在线浓度计 MPR E-Scan 数据稳定 MPR E-Scan 在线折光仪 硫酸浓度专用测量 硫酸工艺浓度控制仪 MPR E-Scan 实时检测 高精度硫酸浓度在线监测 MPR E-Scan 品牌 MPR E-Scan 硫酸在线分析仪 高温工况适用 在线硫酸浓度检测仪 MPR E-Scan 耐腐蚀探头 MPR E-Scan 折光型硫酸浓度仪 无耗材免维护 抗干扰硫酸浓度计 MPR E-Scan 在线测量 工业在线硫酸浓度分析仪 MPR E-Scan 直销 MPR E-Scan 发烟硫酸浓度仪 无惧气泡杂质 硫酸浓度在线监测仪 MPR E-Scan 精准稳定 MPR E-Scan在线硫酸浓度仪 折光原理抗干扰 MPR E-Scan在线折光仪卫生级设计食品制药适用 MPR E-Scan在线折光仪 实时数据传输 4-20mA/RS485

PRODUCT CLASSIFICATION

产品分类

技术文章/ Technical Articles

您的位置:首页  /  技术文章  /  Accurate Green Liquor Density Control with Reduced Maintenance

Accurate Green Liquor Density Control with Reduced Maintenance

更新时间:2019-05-06      浏览次数:1906

In pulp and paper processing, the term "green liquor" refers to a by-product of kraft pulping. It is the dissolved concentration of sodium sulfide, sodium carbonate, and other compounds in solution from the recovery boiler. The measurement and control of its concentration is important in the pulp and paper production cycle. 

Inline refractometers are used to provide continuous density measurement of green liquor in the pulp mill. A major issue in handling green liquor is scale build up and the resulting optical coating on the refractometer sensing head. If scale build-up is controlled for an acceptable amount of time during processing, the maximum accuracy of the refractometer will be achieved and the overall quality of the pulping process is supported. Understandably, it makes great sense that a system of measuring scale potential and a means to automatically clean the sensing head should be implemented.

 

The Electron Machine MPR EScan is used to measure the green liquor dissolved density, or TTA, at two stages in the process: after the green liquor dissolving tank and after the green liquor clarifier. The inline measurement, with the refractometer sensing head installed directly in the main process lines, allows real-time control of green liquor dilution to meet target TTA set-points. The measurement is also used to indicate (and prevent) excessive green liquor density and the resulting dangerous impending crystallization within the dissolving tank, and lower the potential for scaling.

Scaling issues, and therefore accuracy problems, are further reduced with the use of ancillary inline cleaning systems that use pressurized water, heated to the process temperature, to effectively clean the refractometer optical components. The Electron Machine HPC-2 High Pressure Cleaner is one example of a completely integrated system.

The compound result of using a refractometer to keep green liquor density within optimal levels, plus an inline cleaning system, provides an excellent payback both quality control and also with associated maintenance requirements.

关注微信公众号

邮箱:electronmachine@163.com

传真:86-21-34973725

地址:上海市陆翔路111号1号楼707室

Copyright © 2026 上海京度电子科技有限公司版权所有   备案号:沪ICP备10007481号-3   技术支持:仪表网

TEL:13761079671

关注公众号