热门搜索: MPR E-Scan在线折光仪卫生级设计食品制药适用 MPR E-Scan在线折光仪 实时数据传输 4-20mA/RS485 MPR E-Scan在线折光仪防爆设计危险工况适用 MPR E-Scan在线折光仪 耐酸碱 强腐蚀工况专用 MPR E-Scan芳烃油在线浓度分析仪防爆型高精度 MPR E-Scan在线橡胶油折光率分析仪高精度免维护 MPR E-Scan在线浓度仪高精度测量尿素浓度 MPR E-Scan高精度测量发烟硫酸浓度 MPR E-Scan在线折光仪测量硫酸浓度 MPR E-ScanEMC公司E-Scan在线氢氧化锂浓度分析仪应用 MPR E-Scan_Double氧化铝溶出液相全分析苛碱氧铝分析仪 氢氧化钾装置MPR E-Scan一次盐水浓度分析仪 MPR E-Scan氢氧化钾装置中在线硫酸浓度分析仪 MPR E-Scan在线浓度仪氢氧化钾装置KOH浓度分析仪 在线氯化铵浓度分析仪双输出无耗材 MPR E-Scan在线浓度仪氢氧化钾装置盐水分析仪

PRODUCT CLASSIFICATION

产品分类

技术文章/ Technical Articles

您的位置:首页  /  技术文章  /  Accurate Green Liquor Density Control with Reduced Maintenance

Accurate Green Liquor Density Control with Reduced Maintenance

更新时间:2019-05-06      浏览次数:1828

In pulp and paper processing, the term "green liquor" refers to a by-product of kraft pulping. It is the dissolved concentration of sodium sulfide, sodium carbonate, and other compounds in solution from the recovery boiler. The measurement and control of its concentration is important in the pulp and paper production cycle. 

Inline refractometers are used to provide continuous density measurement of green liquor in the pulp mill. A major issue in handling green liquor is scale build up and the resulting optical coating on the refractometer sensing head. If scale build-up is controlled for an acceptable amount of time during processing, the maximum accuracy of the refractometer will be achieved and the overall quality of the pulping process is supported. Understandably, it makes great sense that a system of measuring scale potential and a means to automatically clean the sensing head should be implemented.

 

The Electron Machine MPR EScan is used to measure the green liquor dissolved density, or TTA, at two stages in the process: after the green liquor dissolving tank and after the green liquor clarifier. The inline measurement, with the refractometer sensing head installed directly in the main process lines, allows real-time control of green liquor dilution to meet target TTA set-points. The measurement is also used to indicate (and prevent) excessive green liquor density and the resulting dangerous impending crystallization within the dissolving tank, and lower the potential for scaling.

Scaling issues, and therefore accuracy problems, are further reduced with the use of ancillary inline cleaning systems that use pressurized water, heated to the process temperature, to effectively clean the refractometer optical components. The Electron Machine HPC-2 High Pressure Cleaner is one example of a completely integrated system.

The compound result of using a refractometer to keep green liquor density within optimal levels, plus an inline cleaning system, provides an excellent payback both quality control and also with associated maintenance requirements.