热门搜索: VP-1000粘度计在线检测PVC浆料粘度 A8AF手持式雷达罩潮湿度分析仪 DSA E-Scan台式数显硫酸浓度分析仪 E-Scan在线盐水浓度分析仪 实用型在线硫酸浓度分析仪 MPR E-Scan氧化铝装置循母NK浓度分析仪双输出高精度 在线盐水浓度分析仪氯化钠浓度检测仪 OMNIR型卷烟厂在线水分仪IP69信号双输出 E-Scan在线盐水浓度仪氯化钠浓度分析仪 实用型DCR E-Scan在线硫酸浓度分析仪 OMNIR物联网loT型明胶在线固体近红外水分仪 OMNIR物联网loT型在线碳酸钙水分测定仪 OMNIR物联网loT型灼减附水在线测定仪 SMART III RF物联网loT在线射频水分检测仪 OMNIR型近红外测定仪在线测量输送带水分 物联网loT型活性面筋粉水分在线测定分析仪

PRODUCT CLASSIFICATION

产品分类

技术文章/ Technical Articles

您的位置:首页  /  技术文章  /  Accurate Green Liquor Density Control with Reduced Maintenance

Accurate Green Liquor Density Control with Reduced Maintenance

更新时间:2019-05-06      浏览次数:1399

In pulp and paper processing, the term "green liquor" refers to a by-product of kraft pulping. It is the dissolved concentration of sodium sulfide, sodium carbonate, and other compounds in solution from the recovery boiler. The measurement and control of its concentration is important in the pulp and paper production cycle. 

Inline refractometers are used to provide continuous density measurement of green liquor in the pulp mill. A major issue in handling green liquor is scale build up and the resulting optical coating on the refractometer sensing head. If scale build-up is controlled for an acceptable amount of time during processing, the maximum accuracy of the refractometer will be achieved and the overall quality of the pulping process is supported. Understandably, it makes great sense that a system of measuring scale potential and a means to automatically clean the sensing head should be implemented.

 

The Electron Machine MPR EScan is used to measure the green liquor dissolved density, or TTA, at two stages in the process: after the green liquor dissolving tank and after the green liquor clarifier. The inline measurement, with the refractometer sensing head installed directly in the main process lines, allows real-time control of green liquor dilution to meet target TTA set-points. The measurement is also used to indicate (and prevent) excessive green liquor density and the resulting dangerous impending crystallization within the dissolving tank, and lower the potential for scaling.

Scaling issues, and therefore accuracy problems, are further reduced with the use of ancillary inline cleaning systems that use pressurized water, heated to the process temperature, to effectively clean the refractometer optical components. The Electron Machine HPC-2 High Pressure Cleaner is one example of a completely integrated system.

The compound result of using a refractometer to keep green liquor density within optimal levels, plus an inline cleaning system, provides an excellent payback both quality control and also with associated maintenance requirements.